- Brand Name: MTKY
- Hign-concerned Chemical: None
- DIY Supplies: Electrical
- Battery Included: No
- Origin: Mainland China
- Model Number: XSA800 series
9kHz – 1.5GHz Spectrum Analyzer with Tracking Generator
Specification
– Frequency range 9kHz – 1.5GHz
– -160 dBm Displayed Average Noise Level (DANL)
– Phase noise -80 dBc/Hz @1GHz and offset at 10 kHz
– Total amplitude accuracy <0.7 dB
– 1 Hz minimum resolution bandwidth (RBW)
– EMI pre-compliance test kit, optional EMC test software
– Optional tracking generator (standard tracking generator
hardware, can be remotely upgraded according to needs)
– Waterfall plot graphic, modulation signal quality analysis,
audio demodulation, ect. multiple general and extended
test functions.
– Standard Pass/Fail on-site test and alert function
– Adopt all-digital intermediate frequency technology
– Multiple interfaces: USB Host, USB Device, LAN,
earphone interface, HDMI
– 9-inch LCD, high resolution 1280×800 pixels
|
Frequency |
||||||
|
Frequency Range |
XSA805(TG) |
9 kHz to 500 MHz |
||||
|
XSA810(TG) |
9 kHz to 1 GHz |
|||||
|
XSA815(TG) |
9 kHz to 1.5 GHz |
|||||
|
Frequency Resolution |
1 Hz |
|||||
|
Reference frequency aging rate |
< 1 ppm/year |
|||||
|
Frequency Span |
||||||
|
Span Range |
0 Hz, 100 Hz to max frequency of instrument |
|||||
|
Span Uncertainty |
± span / (sweep points-1) |
|||||
|
SSB Phase Noise(20℃ to 30℃, fc = 500 MHz) |
||||||
|
10 kHz |
< -80 dBc/Hz |
|||||
|
100 kHz |
< -100 dBc/Hz |
|||||
|
1 MHz |
< -115 dBc/Hz |
|||||
|
Bandwidth |
||||||
|
Resolution Bandwidth(-3 dB) |
1 Hz to 1 MHz, in 1-3-5-10 sequence |
|||||
|
Resolution Bandwidth (-6 dB) (EMI) |
200 Hz, 9 kHz, 120 kHz, 1 MHz |
|||||
|
RBW Accuracy |
||||||
|
Resolution Filter Shape Factor (60 dB : 3 dB) |
< 5 typical |
|||||
|
Video |
10 Hz to 1 MHz, in 1-3-5-10 sequence |
|||||
|
Amplitude and level |
||||||
|
Amplitude measurement range |
DANL to +10 dBm, 100 kHz to 10 MHz, Preamp Off |
|||||
|
Reference Level |
-80 dBm to +30 dBm, 0.01 dB by step |
|||||
|
Preamp |
20 dB, nominal, 100 kHz to 1.5 GHz |
|||||
|
Input Attenuator |
XSA805(TG) |
0 to 40 dB, 1 dB by step |
||||
|
Display Average Noise Level (Input attenuation = 0 dB, RBW = VBW = 100 Hz, sample detector, trace average ≥ 50, 20℃ to 30℃, input impedance = 50 Ω) |
||||||
|
Preamp Off |
9 kHz to 1 MHz |
-95 dBm (Typical), <-88 dBm |
||||
|
1 MHz to 500 MHz |
-140 dBm (Typical), <-130dBm |
|||||
|
XSA810(TG) |
500 MHz to 1 GHz |
|||||
|
XSA815(TG) |
500 MHz to 1.5 GHz |
-138 dBm (Typical), <-128 dBm |
||||
|
Preamp On |
100 kHz to 1 MHz |
-135 dBm (Typical), <-128 dBm |
||||
|
1 MHz to 500 MHz |
-160 dBm (Typical), <-150 dBm |
|||||
|
XSA810(TG) |
500 MHz to 1 GHz |
|||||
|
XSA815(TG) |
500 MHz to 1.5 GHz |
-158 dBm (Typical), <-148 dBm |
||||
|
Level Display |
||||||
|
Trace detectors |
positive-peak, negative-peak, normal, sample, RMS, voltage average, quasi-peak |
|||||
|
Trace functions |
clear write, max hold, min hold, average, view, blank, trace math |
|||||
|
Units of level axis |
dBm, dBμW, dBpW, dBmV, dBμV, W, V |
|||||
|
Frequency response |
||||||
|
Preamp Off |
<0.7 dB |
|||||
|
Preamp On |
<1.0 dB |
|||||
|
Difference and Accuracy |
||||||
|
Uncertainty |
fc = 50 MHz, peak detector, preamplifier off, attenuation = 10 dB, input signal level = -10 dBm, 20℃ to 30℃ |
|||||
|
< 0.4 dB |
||||||
|
Level Measurement Uncertainty |
||||||
|
Level measurement uncertainty |
95% confidence level, S/N > 20 dB, RBW = VBW = 1 kHz, preamplifier off, attenuation = 10 dB, -50 dBm < input level ≤ 0 dBm, fc > 10 MHz, 20℃ to 30℃ |
|||||
|
< 0.7 dB |
||||||
|
Tracking Generator (optional) |
||||||
|
Frequency Range |
XSA805(TG) |
100 kHz to 500 MHz |
||||
|
XSA810(TG) |
100 kHz to 1 GHz |
|||||
|
XSA815(TG) |
100 kHz to 1.5 GHz |
|||||
|
Output power |
-40 dBm to 0 dBm |
|||||
|
Output level resolution |
1 dB |
|||||
|
Output flatness |
Relative to 50 MHz |
|||||
|
± 3 dB |
||||||
|
Tracking generator spurious |
Harmonic spurious |
-30 dBc (Tracking generator output power -10 dBm) |
||||
|
Non-harmonic spurious |
-40 dBc (Tracking generator output power -10 dBm) |
|||||
|
Tracking generator to input terminal isolation |
-60 dB (Tracking generator output power 0 dBm) |
|||||
|
Interface |
||||||
|
USB Host, USB Device, LAN, earphone interface, HDMI |
||||||
|
Display |
||||||
|
9-inch TFT LCD, 1280 x 800 pixels |
||||||
|
Appearance |
||||||
|
Dimensions |
375 mm (W) × 185 mm (H) × 120 mm (D) |
|||||
|
Weight |
Approx. 3.7 kg (main device) |
|||||
Product Display



APPLICATION
















Reviews
There are no reviews yet.